USB Data Loggers

 

NEW! SST model logs to 257°F (125°C)
NEW! High accuracy models (TW-USB-2+, TW-USB-2-LCD+)
Temperature, humidity, and dew point
Store up to 32,000 readings (TW-USB-TC, TW-USB-TC-LCD, TW-USB-1-PRO)
Connects directly to PC via USB
LED alarm indication
No cables, dongles or docks
Software included
TW-USB-RT logs to PC in real-time
TW-USB-2-LCD approved for immunization labs

From: To Order

Bookmark and Share

Click and hover to zoom. Click again to view larger image.

Our new USB Data Loggers are a cost-effective solution for logging temperature and humidity data just about anywhere. With built-in alarm LEDs you'll know before you download that there has been a danger condition. Set the logging interval and the start time from the PC software and it's that easy. There are no cables, cradles, or dongles to keep track of.

NEW LCD Display Loggers
Keep visual track of your data with our new LCD data loggers for temperature and humidity. Their high contrast LCDs show Min, Max and current readings for both parameters. The display can be shut down during the log to extend battery life while allowing the user to periodically view the displayed readings.

NEW High Accuracy Temperature and Humidity Loggers
The TW-USB-2+ and TW-USB-2-LCD+ loggers feature high accuracy for temperature, humidity and dewpoint. New! Record critical temperature and humidity data with precision to ±0.6°F (±0.3°C) and ±2% RH.

Connect an External Probe
Connect any type K thermocouple to our TW-USB-TC or TW-USB-TC-LCD loggers and record temperatures to 2000°F depending on the probe selected. Log temperatures in ovens, freezers, and industrial equipment with one of our high temperature thermocouples.

Log in Real-Time
Select our TW-USB-RT and measure temperature directly to your PC in real time. Store up to seven days of data with user-programmable alarm thresholds for both temperature and humidity. The Windows (XP & Vista 32-bit only) software can send email and text alerts and alert audibly via the PC's internal speaker.

Waterproof Applications
With an IP 67 rating, our TW-USB-1, TW-USB-1-PRO, TW-USB-2, and TW-USB-2+ loggers are water resistant and can log in the harshest environments. Store up to 16,382 readings at temperatures to 176°F.

  TW-USB-LITE TW-USB-1 TW-USB-1-PRO
Stainless Steel
Input Temperature Temperature Temperature
Environmental Range +14°F to 122°F
(-10°C to 50°C)
-31°F to 176°F
(-35°C to 80°C)
-40°F to 257°F
(-40°C to 125°C)
Measurement Range +14°F to 122°F (-10°C to 50°C) -31°F to 176°F
(-35°C to 80°C)
-40°F to 257°F
(-40°C to 125°C)
Accuracy ±4.5°F (±2.5°C) ±2°F (±1°C) ±0.4°F (±0.2°C)
Sample Rate 30 minute fixed User selectable 10s to 12h User selectable 1s to 12h
Battery/
Battery Life
CR1620/
1-month life
3.6V 1/2AA/
1 year life
3.6V 1/2AA/
1 year life
Resolution 2°F (1°C) 1°F (0.5°C) 0.2°F (0.1°C)
Alarms Hi/Low programmable Hi/Low programmable Hi/Low programmable
Alarm Status Red/Green LED Red/Green LED Red/Green LED
Interface USB USB USB
Memory 4,080 readings 16,382 readings 32,510 readings
Logging Start Delay or immediate Delay or immediate Delay or immediate
IP Rating
(water resistance)
na IP67 IP67
Software Windows 98, 2000, XP, Vista Windows 98, 2000, XP, Vista Windows 98, 2000, XP, Vista

 

  TW-USB-2 /
TW-USB-2-LCD
TW-USB-2+ /
TW-USB-2-LCD+
Input Temperature, Humidity, Dewpoint;
LCD Display (on LCD unit)
High-Accuracy Sensor—
Temperature, Humidity, Dewpoint;
LCD Display (on LCD unit)
Environmental Range Temp: -31°F to 176°F
(-35°C to 80°C)
Humid: 0% to 100%
Temp: -31°F to 176°F
(-35°C to 80°C)
Humid: 0% to 100%
Measurement Range Temp: -31°F to 176°F (-35°C to 80°C)
Humid: 0% to 100%
Temp: -31°F to 176°F (-35°C to 80°C)
Humid: 0% to 100%
Accuracy Temp: ±1°F (±0.5°C);
Humid: ±3%
Dewpoint: ±2°F (±1.1°C)
Temp: ±0.6°F (±0.3°C);
Humid: ±2%
Dewpoint: ±2°F (±1.1°C)
Sample Rate User selectable 10s to 12h User selectable 10s to 12h
Battery/
Battery Life
3.6V 1/2AA/
1 year life
3.6V 1/2AA/
1 year life
Resolution Temp: 1°F (0.5°C),
Humid: 0.5%
Temp: 1°F (0.5°C),
Humid: 0.5%
Alarms Hi/Low programmable for both Hi/Low programmable for both
Alarm Status Red/Green LED Red/Green LED
Interface USB USB
Memory 16,382 readings per channel 16,382 readings per channel
Logging Start Delay or immediate, and push-button on LCD unit Delay or immediate, and push-button on LCD unit
IP Rating
(water resistance)
IP67
(TW-USB-2 only)
IP67
(TW-USB-2+ only)
Software Windows 98, 2000, XP, Vista Windows 98, 2000, XP, Vista

 

  TW-USB-RT TW-USB-TC /
TW-USB-TC-LCD
Input Real-time
Temperature, Humidity, Dewpoint
Temperature: K, J, or
T Type Thermocouple;
LCD Display (on LCD unit)
Environmental Range Temp:
+14°F to 140°F
(-10°C to 60°C)
Humid: 0% to 100%
+14°F to 104°F
(-10°C to 40°C)
Measurement Range Temp: +14°F to 140°F (-10°C to 60°C)
Humid: 0% to 100%
-328°F to 2372°F
(-200°C to 1300°C) for
K type depending on thermocouple used.
Accuracy Temp: ±3°F (±1.5°C);
Humid: ±4.5%
Dewpoint: ±5°F (±2.5°C)
±2°F (±1°C)
Sample Rate 1 second fixed User selectable
1s to 12h
Battery/
Battery Life
N/A - powered by USB port. Must remain connected. 3.6V 1/2AA/
6 month life
Resolution Temp: 1°F (0.5°C),
Humid: 0.5%
1°F (0.5°C)
Alarms Hi/Low programmable Hi/Low programmable
Alarm Status Email, text, audible PC alerts Red/Green LED
Interface USB USB
Memory Stores 7 days to PC file 32,510
Logging Start Real time Delay or immediate, and push-button on LCD unit
IP Rating
(water resistance)
na na
Software Windows XP, Vista (32-bit only) Windows 98, 2000, XP, Vista

NEW! High accuracy model TW-USB-2+ with temperature accuracy to ±0.3°C, and humidity accuracy to ±2%.


Plugs directly into USB port.
No cables or adapter required.
Software is included.


Click image to enlarge graph

View data graphically or export to spreadsheet.

Click here to download the EasyLogUSB software (v5.4).

Click here to download the EasyLog Real-Time software. (For use with TW-USB-RT only)


Plug any type K, J, or T thermocouple into the TW-USB-TC logger.
Click here to order probes.


Rugged Metal Case
Fits TW-USB-1 or -2, watertight to IP67/NEMA-4X.

Cal Cert

NIST-Traceable Temperature Calibration

Model: CAL-2PT

  • 2-Point calibration
  • Traceable certificate
2-point temperature calibration performed in ThermoWorks' NIST-Traceable calibration lab. Includes calibration report and actual test data.


Cal Cert

NIST-Traceable RH Calibration

Model: CAL-RH2PT

  • 2-Points: 30%, 60%
  • Lab calibration using certified RH sources
  • Single ambient temperature
2-point humidity calibration performed in ThermoWork's NIST-Traceable calibration lab. Includes calibration report and actual test data. Includes a single temp at ambient.

To Order:

TW-USB-LITE Temperature Data Logger, Economy
TW-USB-1 Temperature Data Logger, IP67
TW-USB-1-PRO Temperature Data Logger, Stainless Steel, IP67
TW-USB-2 Relative Humidity & Temperature & Data Logger, IP67
TW-USB-2-LCD Relative Humidity & Temperature Data Logger with LCD
TW-USB-2+ High Accuracy Relative Humidity & Temperature & Data Logger (±0.3°C / 2%RH), IP67
TW-USB-2-LCD+ High Accuracy Relative Humidity & Temperature & Data Logger, (±0.3°C / 2%RH), with LCD
TW-USB-RT Relative Humidity & Temperature Data Logger, Real-time
TW-USB-TC Thermocouple Temperature Data Logger, Accepts Type K Probes
TW-USB-TC-LCD Thermocouple Temperature Data Logger with LCD, Accepts Type K Probes
TW-USB-CASE Rugged Metal Case. Fits TW-USB-1
839-100 Replacement battery SL350, 3.6V Lithium. 1/2 AA
BATT-2/3AA Replacement battery SL350, 3.6V Lithium, 2/3 AA (USB-1-PRO)

Our Company