| Handheld Meters | |||
![]() |
Mini Handheld Thermocouple MeterModel: MTC
|
Range: -83 to 1999°F (-64 to 1400°C) Accuracy: ±1% or 1.8°F(1°C), whichever is greater. ![]() ![]() ![]() |
|
![]() |
EcoTemp Alarm ThermometerModel: 810-960
|
Range: -58 to 392°F (-50 to 200°C) Accuracy: ±1.8°F from -58 to 302°F (±1°C from -50 to 150°C) ![]() ![]() ![]() |
|
![]() |
Thermamite 5Model: 261-555
|
Range: -22 to 575°F (-30 to 300°C) Accuracy: ±1%, ±1 digit ![]() ![]() |
Closeout Pricing
|
![]() |
Thermamite 1Model: 262-551
|
Range: -49.9 to 199.9°F (-50 to 199.9°C) Accuracy: ±0.9°F (±0.5°C), ±1 digit ![]() ![]() |
Closeout Pricing
|
![]() |
Two-Channel Thermocouple with AlarmModel: TW8060
|
Range: -328 to 2372°F (-200 to 1300°C) Accuracy: -148 to 2372°F: ±0.1% + 1.4°F ![]() ![]() ![]() ![]() |
Save on kits!
|
| |
Splash-Proof Surface Thermapen™Model: 231-212
|
Range:-58.0 to 572.0°F (-49.9 to 299.9°C) Accuracy: ±0.7°F (±0.4°C) from -58 to 392°F (-49.9 to 199.9°C) ![]() ![]() ![]() |
Closeout Pricing
|
![]() |
ThermamiteModel: 261-550
|
Range: -58 to 572°F (-50 to 300°C) Accuracy: ±1.8°F (±1°C) ±0.1% ![]() ![]() ![]() |
|
![]() |
Food CheckModel: 221-048
|
Range: -58 to 572°F (-50 to 300°C) Accuracy: ±0.7°F (±0.4°C) from -58 to 390°F (-50 to 199°C) ![]() ![]() ![]() |
|
![]() |
Therma KModel: 221-041
|
Range: -148 to 2501°F (-100 to 1372°C) Accuracy: ±0.5°F (±0.28°C) from 32°F to 212°F (0°C to 100°C) ![]() ![]() ![]() ![]() |
Save on kits!
|
![]() |
Therma K-PlusModel: 221-051
|
Range: -148 to 2501°F (-100 to 1372°C) Accuracy: ±0.5°F (±0.28°C) from 32°F to 212°F (0°C to 100°C) ![]() ![]() ![]() ![]() |
Save on kits!
|
![]() |
Therma WaterproofModel: 232-101
|
Range: -148 to 2500°F (-100 to 1372°C) Accuracy: ±0.7°F (±0.4°C) from 14 to 158°F (-10 to 70°C) ![]() ![]() ![]() |
Save on kits!
|
![]() |
Pro Surface ThermapenModel: 231-279
|
Range: -58.0 to 572.0°F (-49.9 to 299.9°C) Accuracy: ±0.7°F (±0.4°C) from -58 to 392°F (-49.9 to 199.9°C) ![]() ![]() ![]() |
|
![]() |
Therma 20Model: 226-040
|
Range: -40 to 302 °F (-39.9 to 149.9°C) Accuracy: ±0.7°F (±0.4°C) from 14 to 158°F (-10 to 70°C), includes probe error ![]() ![]() ![]() |
|
![]() |
Therma Differential Thermocouple MeterModel: 231-022
|
Range:-148 to 2501.6°F (-100 to 1372°C) Accuracy: ±0.72°F (±0.4°C) ±1% of reading ![]() ![]() ![]() |
|
![]() |
Therma 22 Dual Sensor Food Industry MeterModel: 227-022
|
Range: Thermistor: -40 to 302 °F (-39.9 to 149.9°C) Accuracy: Thermistor: ±0.7°F (±0.4°C) from 14 to 158°F (-10 to 70°C) ![]() ![]() ![]() ![]() |
|
![]() |
Therma 22 Plus
|
Range: Thermistor: -39.8 to 301.8°F (-39.9 to 149.9°C) Accuracy: Thermistor: ±0.72°F (±0.4°C) 14 to 158°F (-10 to 70°C) otherwise ±1.8°F (±1°C) ![]() ![]() ![]() ![]() |
|
![]() |
MicroTherma 2KModel: 221-092
|
Range: -346 to 3200°F (-210 to 1760°C) Accuracy: ±0.4°F (±0.2°C), ±1 digit ![]() ![]() ![]() ![]() |
Save on kits!
|
![]() |
MicroTherma 2TModel: 227-193
|
Range: -346 to 770°F (-210 to 410°C ) Accuracy: ±0.4°F (±0.2°C), ±1 digit ![]() ![]() ![]() ![]() |
Save on kits!
|
![]() |
ThermaPlus Waterproof Thermocouple MeterModel: 221-071
|
Range: -148°F to 2501°F (-100 to 1372°C) Accuracy: 32 to 212°F:
±0.5°F (0.28°C), ±0.1% ![]() ![]() ![]() ![]() |
Save on kits!
|
![]() |
CaterTemp Waterproof Thermocouple MeterModel: 221-059
|
Range: -58°F to 571.8°F (-50 to 299.9°C) Accuracy: 32 to 212°F (0 to 100°C):
±0.5°F (0.28°C), ±0.1% ![]() ![]() ![]() ![]() |
|
![]() |
Saf-T-Log Paperless HACCP ThermometerModel: 292-701
|
Range: -148 to 2500°F (-100 to 1372°C) Accuracy: ±0.7°F / 0.4°C ![]() ![]() ![]() ![]() ![]() |
Introductory Price:
|
![]() |
Therma CheckModel: 226-042
|
Range: -40 to 302°F (-39.9 to 149.9°C) Accuracy: ±0.5°F (±0.3°C) to 158°F (70°C) ![]() ![]() ![]() |
|
![]() |
Therma ChecK PlusModel: 232-042
|
Range: -40 to 302°F (-39.9 to 149.9°C) Accuracy: ±0.7°F (±0.4°C) from 14 to 158°F (-10 to 70°C) ![]() ![]() ![]() |
|
![]() |
Precision ThermometerModel: 222-553
|
Range: -328 to 1562°F (-200 to 850°C) Accuracy: ±0.4°F (±0.2°C) ![]() ![]() ![]() ![]() |
|
![]() |
Precision Plus ThermometerModel: 222-550
|
Range: -328 to 1562°F (-200 to 850°C) Accuracy: ±0.1°F (±0.05°C) ![]() ![]() ![]() ![]() |
|
![]() |
Splash-Proof Reference Thermapen™Model: 222-213
|
Range: -94.00 to 392.00°F (-69.99 to 199.99°C) Accuracy: ±0.07°F / 0.4°C ![]() ![]() |
|
![]() |
Reference ThermometerModel: 222-555
|
Range: -328 to 391°F (-199.9 to 199.9°C) Best Accuracy: ±0.1°F (±0.05°C) ![]() ![]() ![]() |
|
![]() |
P700 Series Precision Handheld Reference ThermometerModel: P750 / P755
|
Range: -328°F to 1562°F (-200°C to 850°C) Accuracy: ±0.03°C ![]() ![]() ![]() ![]() ![]() |
From |
![]() |
Printing ThermometerModel: 9882
|
Range: -328 to 2498°F (-200 to 1370°C) Accuracy: ±0.1% of reading + 1.4°F (+ 0.7°C) ![]() ![]() ![]() ![]() ![]() ![]() |
|
![]() |
Wireless HACCP Recording ThermometerModel: RTR-61-110
|
Range: -13 to 455 °F (-25 to 235°C) Accuracy: ±0.9°F (±0.5°C) from 185 to 230°F (85 to 110 °C) ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
From |
| Icon Legend | |
![]() |
Type K Thermocouple: Meter includes input for type K thermocouple probe. |
![]() |
Type T Thermocouple:Meter includes input for type T thermocouple probe. |
![]() |
Thermistor Probe:Meter includes input for thermistor probe. |
![]() |
RTD Probe:Meter includes input for RTD (Resistance Temperature Detector) probe. |
![]() |
USB-Enabled: Includes a USB port for easy downloading of stored data to your computer. |
![]() |
Water-Resistant Rated: Indicates that a product has been tested for protection against the ingress of water into the equipment. See the product specification table for the actual test rating and see our IP Table. |
![]() |
NSF Certified: Indicates that the design, materials, production process and quality controls used in the production of a product have been verified and certified for food safety by NSF. See NSF.org. |
![]() |
NSF Certified Component: Indicates that the design, materials, production process and quality controls used in the production of a product have been verified and certified for food safety by NSF. See NSF.org. |
![]() |
Alarm: Includes a feature that will alert you via visual and/or audible cues (or, in some cases, email or texts) when a reading is outside user-specified limits for safety or desirability. |
![]() |
NIST-Traceable Certificate: Indicates the inclusion of a certificate showing the traceability of a device to standards of accuracy set by the National Institute of Standards and Technology (see NIST.gov). |
![]() |
°C / °F Switchable: Indicates that readings can be displayed in either degrees Celsius or degrees Fahrenheit. |
![]() |
Min / Max Feature: Includes a feature allowing you to quickly display the maximum and minimum values measured during a specified period of time. |
![]() |
Data Logging-Capable: Shown when a device has the ability not only to display readings in the device for later recall or for downloading to a PC. |